Use of Micropipettes
Proper Use Of Micropipettes

A micropipette is one of the instruments that is usually used in science laboratories .Micropipette are used to accurately measure and dispense small volumes of liquid . The capacity of a micropipette can range from less 1µl to 1000µl (1ml) .There are glass pipettes , air displacement pipettes , and positive displacement pipettes . Mostly , the air displacement pipettes and positive displacement pipettes are used . Firstly , the piston is moved to the appropriate position when the volume is set . Next , when the operating button is pressed to the first stop , the piston is expelled the same volume of air as indicated on the volume setting . After immersing the tip into the liquid , the operating button is released. It is usually used for applications like DNA amplification techniques . When the operating button is pressed to the stop , the piston descends to the tip opening . After the tip is immersed into the liquid , the operating button is released . The plunger is then raised and a partial vacuum is created . This causes the liquid to enter the tip . When the operating button is pressed again , the piston descends , expelling the liquid from the tip.
We need to optimize volume range by selecting the correct volume pipette . We must work in the 35% to 100% volume range for best accuracy and precision . Besides that , the tip immersion angle also plays an important role . Nextly, the micrometer setting must be done using the correct technique . If filled , we should not lay the pipette down or hold more than 20º from vertical . Lastly , we should not twist the volume higher than the maximum for the pipette . We should always check and clean the shaft and piston on a regular basis . Next , we should always clean pipette if aerosol or splashing occurs without use of a filter tip

You May Also Find These Documents Helpful

  • Better Essays

    Gas Stoich Honors

    • 910 Words
    • 4 Pages

    8. Holding your finger over the hole in the rubber stopper, invert the tube into the 400-mL beaker of water. Clamp the gas collection tube in place on the ring stand so that the stoppered end of the tube is under the water but not touching the bottom of the beaker.…

    • 910 Words
    • 4 Pages
    Better Essays
  • Good Essays

    After there is no more liquid in the funnel, take the filter paper and lay it somewhere to air dry.…

    • 432 Words
    • 2 Pages
    Good Essays
  • Good Essays

    6. Using a micropipette, a 10 micro liter sample is dispensed into well by holding the tip of the micropipette just inside the well so as not to puncture the bottom.…

    • 950 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Genetics Module 7 Lab 2

    • 1676 Words
    • 7 Pages

    4. Why do you need a large box of micropipettor tips? You will need a new one each time it goes into a new solution, avoiding cross contamination and keeping integrity to the experiment. Because there are several steps, you will need a large supply to properly carry out the testing.…

    • 1676 Words
    • 7 Pages
    Good Essays
  • Good Essays

    Basic Lab Measurements

    • 465 Words
    • 2 Pages

    Transfer the water from the beaker to a 50mL graduated cylinder and record the measurement.…

    • 465 Words
    • 2 Pages
    Good Essays
  • Satisfactory Essays

    5.03 FLVS Chem Lab

    • 686 Words
    • 4 Pages

    1. Move the lid of the container up or down. Record the resulting volume and pressure inside the container.…

    • 686 Words
    • 4 Pages
    Satisfactory Essays
  • Powerful Essays

    C311

    • 489 Words
    • 4 Pages

    The purpose of the pipet calibration is to determine the accuracy and precision of 10ml of water at room temperature by using a 10ml volumetric pipet. Also, analyzing the analytical balance and the density of water from literature reference.…

    • 489 Words
    • 4 Pages
    Powerful Essays
  • Powerful Essays

    2. When performing the following, NEVER TOUCH THE TIP OF THE PIPET TO THE SOLUTION…

    • 978 Words
    • 4 Pages
    Powerful Essays
  • Satisfactory Essays

    Ionic Reactions

    • 354 Words
    • 2 Pages

    2. When performing the following, NEVER TOUCH THE TIP OF THE PIPET TO THE SOLUTION…

    • 354 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Experiment 1 Protocol

    • 402 Words
    • 3 Pages

    6. Use the 100 mL graduated cylinder to measure and pour 100 mL of water into beaker “B”. Gently pipette…

    • 402 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Intro to Lab. Procedure

    • 1450 Words
    • 6 Pages

    2- Confirm that your 10.00 mL volumetric pipet is clean by filling to above the mark with deionized water and then letting it drain. Your pipet is a transfer pipet is a transfer pipet that is calibrated “to deliver” (TD) rather than “to contain” (TC). The last drop of liquid should not drain out of the tip of a TD pipet in normal use. However, there should be no water drops left on the side walls. The presence of such drops indicates that your pipet is dirty.…

    • 1450 Words
    • 6 Pages
    Good Essays
  • Good Essays

    Lab Report Help

    • 1320 Words
    • 6 Pages

    5. Connect a rubber stopper to the pressure probe and later to the flask with valve closed so that absolutely no hydrogen gas will escape.…

    • 1320 Words
    • 6 Pages
    Good Essays
  • Good Essays

    Lab Report Chemistry Lab

    • 598 Words
    • 3 Pages

    5. Then tip the cylinder to about 45 degrees then put sample into it slowly, DON’T spill any water or have to restart. Make sure no air bubbles are clinging. Then take down final volume of water cylinder.…

    • 598 Words
    • 3 Pages
    Good Essays
  • Better Essays

    Beers Law

    • 879 Words
    • 4 Pages

    Step #4: Using the 1mL fine tip pipet add the appropriate number of drops of distilled water to each well. (Refer to data table 1 in lab assistant section)…

    • 879 Words
    • 4 Pages
    Better Essays
  • Powerful Essays

    We noticed the calibration marks on the beakers were taken only to be an approximate guide to volume because the marks were placed at greater intervals. This did not allow for precise measurements. The 25-mL volume dispensed by the pipet was much more precise than using the beaker and more precise than the graduated cylinder as well…

    • 1066 Words
    • 5 Pages
    Powerful Essays