Precision describes the closeness of results that have been obtained in exactly the same way while accuracy indicates the closeness of the measurement to its true value. This experiment was used to determine the accuracy and precision of different volumetric measuring devices, as well as determining the density of an unknown metal. This lab was to help understand the application to volumetric measurements.
Part 1: First, the next-to-smallest beaker was cleaned, dried, and weighed on the scale where it’s mass was determined. The container was then tared so the scale would only read the mass of the water. The smallest beaker was used to measure out 14 mL of water. Then, that waster was poured into the pre-weighed beaker and put on the scale. Once the measurement was recorded the beakers were both cleaned and dried. This process was repeated two more times. Second, a 100 mL graduated cylinder was used to measure out 14 mL of water. Then, that water was poured into the pre-weighed beaker and put on the scale. Once the measurement was recorded, the beaker and graduated cylinder were both cleaned and dried. This process was repeated two more times. Third, a 25 mL buret was used to measure out 14 mL of water. Then, that water was poured into the pre-weighed beaker and put on the scale. Once the measurement was recorded, the beaker and buret were both cleaned and dried. This process was repeated two more times. After recording the mass using three different volumetric devices, each with three trials, density was calculated for each volumetric device and trial. Then, the trials were averaged. This concluded that the buret was the most accurate measuring device. Last, the average mass of water and standard deviation was calculated, confirming the results that the buret was the most accurate measuring device.
Results/Data:
Table 1: Mass of 14 mL of water in different volumetric devices

Volumetric Device | Mass (g) | | Measurement 1 | Measurement 2 |

You May Also Find These Documents Helpful

  • Good Essays

    6.03 Calorimetry Lab

    • 529 Words
    • 3 Pages

    Approximately 40 mL of the ionized water was added to the 100 mL beaker, then in a 10-mL graduated cylinder, 5-mL of HCl was measured then added to the 100-mL beaker of water. The 100 mL beaker was then placed on the assembled ring stand.…

    • 529 Words
    • 3 Pages
    Good Essays
  • Good Essays

    5. Select the distilled water in the beaker and add 25mL to the graduated cylinder.…

    • 1598 Words
    • 7 Pages
    Good Essays
  • Good Essays

    6.03 Calorimetry Lab

    • 992 Words
    • 4 Pages

    Using the buret to read the volume of water is a source of random error because it is marked to the nearest 0.1mL. Therefore, our data could be above or below the actual volume of water in the buret because we took our reading to the nearest 0.01mL, which increases our uncertainty level. Along with taking our volume readings to the nearest 0.01mL, a random error also arose when we took the reading of the temperature of the water. The thermometer only read to the nearest tens places, therefore our readings went to only the tenths place which could have been measured inaccurately giving rise to more uncertainty and random error within the lab. We were able to limit our uncertainty level when taking the masses of the beaker with and without water, by using the analytical balances which read to the nearest ±0.0001g.…

    • 992 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Gainless Steel Lab

    • 685 Words
    • 3 Pages

    5. While the cylinder is heating, measure approximately 100 mL of water in a graduated cylinder. Record the mass of the water to one decimal place. Then pour the water into a plastic-foam cup.…

    • 685 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Basic Lab Measurements

    • 465 Words
    • 2 Pages

    This lab experiment displays the accuracy of scientific measuring equipment. This experiment also helps to familiarize the students with these instruments.…

    • 465 Words
    • 2 Pages
    Good Essays
  • Satisfactory Essays

    Chem Lab 2 Report

    • 942 Words
    • 9 Pages

    Procedure: In the experiment, I use devices such as a ruler, beakers, flasks, a scale and cylinders to measure the values of each object and liquid.…

    • 942 Words
    • 9 Pages
    Satisfactory Essays
  • Good Essays

    Insert the tiny pellets of aluminum which you recorded the mass in step 1 of this procedure in the measuring cylinder containing water and record the final volume.…

    • 1478 Words
    • 6 Pages
    Good Essays
  • Better Essays

    Lab 9

    • 915 Words
    • 4 Pages

    1. Graduated cylinder to measure out approximately 100 mL of distilled water and place it in a very clean glass. In a separate clean glass, measure out 100 mL of tap water.…

    • 915 Words
    • 4 Pages
    Better Essays
  • Good Essays

    Density Lab

    • 463 Words
    • 2 Pages

    2. Measure Volume by using water displacement method. Fill a 50 mL graduated cylinder about half full with water, measure the volume, and record volume of water alone in Data Table 1. Measure the volume and record the measurement as “volume of water+sample” IN Data Table 1. Find the “volume of the solid” subtract volume of the “water alone” from the “volume of water+sample”.…

    • 463 Words
    • 2 Pages
    Good Essays
  • Satisfactory Essays

    Unknown liquid

    • 264 Words
    • 2 Pages

    III. Procedure: 1.We massed an empty 10mL graduated cylinder to the nearest .01g. 2.Then, we filled the graduated cylinder with 4.0-5.0 mL of distilled water, 3.massed it to the nearest 0.1 ml and 4. recorded the data. Then to determine the density of the unknown liquid; we repeated the steps.…

    • 264 Words
    • 2 Pages
    Satisfactory Essays
  • Powerful Essays

    Finding Density Lab

    • 1151 Words
    • 5 Pages

    been previously done. After the mass of water was measured, the beaker and graduated cylinder were…

    • 1151 Words
    • 5 Pages
    Powerful Essays
  • Good Essays

    pre lab

    • 405 Words
    • 2 Pages

    We went from a big flask to a small beaker to an even smaller pipette. We used a scale to get the appropriate weight of the water in the different beakers.…

    • 405 Words
    • 2 Pages
    Good Essays
  • Powerful Essays

    Density of Sprite

    • 1742 Words
    • 7 Pages

    In the first phase of the experiment, the 25 ml Pipette is used to measure the volume and mass of the solution. Another beaker was in grams. Pipette was used to measure 25ml of regular Sprite. The solution was drawn the beaker and its mass was measured on the electronic balance. Mass of the solution was then calculated by subtracting beaker's weight and beaker with solution's weight.…

    • 1742 Words
    • 7 Pages
    Powerful Essays
  • Satisfactory Essays

    Procedure: I used a measuring device such as a ruler, balance or volumetric flask to determine the values for each measurement.…

    • 1411 Words
    • 11 Pages
    Satisfactory Essays
  • Powerful Essays

    steel wool was used in place of sandpaper to remove the zinc coating on the nails;…

    • 1905 Words
    • 9 Pages
    Powerful Essays